DISCHARGE CAPABILITY

Tel. +33 (0) 3 83 80 78 08
Calculate the slope

PAM DRAINAGE PIPE SYSTEMS
APPLICATION
For the dimensioning of rainwater and wastewater systems, the nominal sizes can be determined using the dimensioning tables in the appendix of DIN 1986-100. However, these tables only represent the discharge capacity of the smallest permissible inner diameter of the values specified in DIN EN 12056 values.
If the pipe material is known at the latest during the execution planning, the specific discharge capacities should be determined for a differentiated calculation on the basis of the actual internal diameter of the respective drainage pipe system should be used for a differentiated calculation.
Example of wastewater pipe Filling level h/d = 1.0 with slope 1 cm/m
DN |
PAM-GLOBAL® drainage pipes |
DIN 1986-100, A3 |
DIFFERENCE |
100 |
3,0 l/s |
2,5 l/s |
+20% |
125 |
5,3 l/s |
3,9 l/s |
+36% |
150 |
8,5 l/s |
7,7 l/s |
+10% |
DOWNLOAD OUR BROCHURE FOR MORE INFORMATION
The table in the brochure provides the exact discharge capability values of the PAM drainage pipe systems for filling levels 50%, 70% and 100%.