Access pipe rectangular - DN150 - SMU S
Code article : 179198
Description
Part of the Standard drainage system, the SMU S rectangular access pipe allows you to enter the network. The access pipe is made up of a cast iron body and a rectangular cover plate, coated with a reddish-brown epoxy film applied by cataphoresis. PAM Building cast iron SMU S range complies with European standard EN 877 and has remarkable fire protection properties as well as exceptional acoustic performances.
Product variants
Article | DN | dn | Angle | Length | Height | Width | Weight |
---|---|---|---|---|---|---|---|
179197 | 125 | - | - | 190 | 370 | 169 | 10.3 |
179198 | 150 | - | - | 215 | 395 | 192 | 14.5 |
179199 | 200 | - | - | 262 | 435 | 242 | 22 |
179200 | 250 | - | - | 330 | 540 | 307 | 38.5 |
179201 | 300 | - | - | 380 | 610 | 358 | 50 |
All dimensions are in mm and nominal weights are in kg
Technical infos & product description
Product description
Part of the Standard drainage system, the SMU S rectangular access pipe allows you to enter the network. The access pipe is made up of a cast iron body and a rectangular cover plate, coated with a reddish-brown epoxy film applied by cataphoresis. PAM Building cast iron SMU S range complies with European standard EN 877 and has remarkable fire protection properties as well as exceptional acoustic performances.
Recommended use :
- Rainwater
- Valve water
- Wastewater
Major benefits :
- Performances guaranteed with marks delivered by third party.
- High level of fire safety with the excellent fire resistance up to 240 minutes according to configuration (mostly requires no special fire protection saving time and cost).
- Best acoustic comfort.
- Easiness of installation due to mechanical couplings assembled with simple tools.
- Adaptable to all configurations with available accessories connecting cast iron with other materials.
- Limited maintenance operation thanks to technical and mechanical properties of cast iron.
Technical infos
- Hot water resistance: 24h at 95°C.
- Thermal cycle resistance: 1500 cycles between 15°C and 93°C.
- Chemical resistance for 2 ≤ pH ≤ 12.
- Salt spray resistance internal coating: more than 350 h.
Coating description :
Coating: red-brown, anti-corrosive cataphoresis epoxy, average dry film thickness 70 μm.- Material : Cast-iron
- Industry product standards : NF EN877
- Range Fire Classification : A1
- Acoustic Performance : Lsc ≤ 10 dB(A) & LaA = 47 dB(A) according to EN 14366 with 2L/s.
- Percentage of Recycled Content : 97%
- Recycling Information : 100% Recyclable